Deltronic Optical Comparator User Manual

Deltronic Optical Comparator User Manual' title='Deltronic Optical Comparator User Manual' />Deltronic Optical Comparator User ManualProlink Software Support QC Gage. The Gage. Port NT provides two reading modes, Static and Dynamic. Static mode. takes a single reading and transmits it to QC Gage. Dynamic mode takes a series. You. can have some gages in static mode and some in dynamic mode connected to the. Gage. Port NT, but you must be careful how you configure the foot switches. Gage. Port to send data. If you. use dynamic mode, you must make 3 features in your QC Gage Spec Plan for each. The readings come in as. Min, Max, and TIR. If you want QC Gage to check the mode, specify units of. Static for a feature that should be measured in static mode and units of Min. Max, and TIR respectively for the three features generated by a reading in. The autodetect capability allows quick and easy setup of new gages, and allows. The Gage. Port NT allows you to burn in a gage type and settings so when you. Gage. Port your old settings for that gage come back. See the Configuration notes section for details. A Gage. Port with 4 ports can support 4 gages but only has 2 foot switches. You. can configure each port to respond to either, neither, or both foot switches. This means you can set up a system so pressing foot switch 1 causes gages 1 and. Send button on the gage or press. Get Reading button on QC Gage. Configuring. the Gage. Port NT for the first time can take an hour or more and be somewhat. Sigma Xl Serial Number. Prolink makes the. Background. The Gage. Port has three types of memory permanent, semi permanent, and. Smart. Cables here. The permanent memory. Gage. Port how to handle. Gage. Port to. All we really care. Deltronic_DH14-MPC_Optical_Comparator_2.jpg' alt='Deltronic Optical Comparator User Manual' title='Deltronic Optical Comparator User Manual' />Deltronic Optical Comparator User ManualPlease tell advertisers you found their machines in LOCATOR Sec. LOCATOR. August 2015. PM. This section gives additional information about some of the gages supported by QCGage. Limitations, extra features, and unexpected behaviors are documented. Issuu is a digital publishing platform that makes it simple to publish magazines, catalogs, newspapers, books, and more online. Easily share your publications and get. Gage. Port NT to its. The second type of memory, semi permanent, is. This memory is not cleared when you. Gage. Port NT, so anything put here is permanent until you. Gage. Port to change it. When you configure the output. The last type of memory we. This gets reset every time you unplug the Gage. Port. Readings go here. This means that if. Gage. Port checks the gage every time you power the. Gage. Port up so make sure the gage is plugged in You can copy the gage name. Gage. Port NT it uses the one you told it instead of autodetecting. This also. preserves settings like static vs. You can clear this setting by. The Gage. Port NT accepts commands and sends data by RS2. The Gage. Port is case. As is not the same as AS or as. It is also. timing sensitive on many commands, and will reject a command sent too quickly. For this reason we recommend using 1. Gage. Port NT, even though it can support higher speeds. To prevent. delays in commands you send while configuring the Gage. Port, you can type the. Each port on the Gage. Check Machinesused. CNC machines, lathes, mills, grinders, and more. Live Onsite and Global Webcast Auction AMERICAN RENEWABLE TECHNOLOGIES 40,000 SF STATE OF THE ART METAL FABRICATION PLANT Starts Wednesday, November 8, 2017 10. Liquid Asset Partners LLC Current Liquidations Auctions Negotiated Sales. Liquidation, Auction, Appraisal. Store Closings, Going Out of Business Sales, and Chapter. Port can be set or commanded independently. You specify a. port to receive the command by preceding a command with an attention character. The attention character is different for each port. All attention characters. The attention character for the first port is A, the. B, and so on. For example, to send the r. Crand assuming a gage was connected to port 3, was turned on, and was in static. Most of the examples. A but you could apply them to ports 2, 3. A with a B, C, etc. How to start. The first step is to set the RS2. Take the shell off the. RS2. 32power connector for the Gage. Port. Inside the shell are DIP switches for. Set the switches for printer. CRLF, 1. 20. 0 baud, no parity. You can use 9. 60. Gage. Ports input buffer and so little data passes at a. The next step is to connect the gages to the Gage. Port and the. serial power cable between the Gage. Port and the computer and plug the power. Start Microsofts Hyper. Terminal or the terminal emulator of your. Choose the serial port you connected the Gage. Port NT to, set its baud. Close and reopen the serial port to make sure the new settings. You may also want to save these settings so you can easily. Gage. Port in the future. You should now be able to type. Aiand get a response similar to the following one. P0. 1,M2. 10. 4,2. U0. D0,G0. 990. PUNH the exact response is not important, but there should be no strange characters. If you did not get a response, or the response is garbled, you have a problem. Gage. Port and cannot proceed until it is. The QC Gage manual contains an appendix with a section on debugging. Gage. Port manual describes the cable switch settings. If your Gage. Port has been used and possible configured before, you should reset. The Gage. Port NT will display the. Metal Gear Solid 3 Subsistence Ps2 Torrent Iso Psp. Emulating 2. 10. 4 Number of ports4. HHexdump. PPoke addr. Kchec. Ksum calculation. RReset and run. Type R to reset it to factory fresh condition, wait about 1. Remove the jumper, put the cover back on. Gage. Port, and attach the serial power cable again. What to set. Remember that typing too slow, or forgetting to press Enter after typing a. Gage. Port to reject the command Disable the transmission of headers on power up with the following line. You do. not need to repeat it for each port because all ports share the same output. You do not need to save this setting, it automatically goes into. Aoh optionalSet the foot switch action for each port. The format is Aw followed. A to respond to. If you want port A. Repeat with ports B, C, and D if. You do not need to save foot switch settings, they automatically go. To make foot switch 1 cause gages 1 and 4 to send. Gage. Port. Aw. 1,2. Bw. 2Cw. Dw. 1optionalForce power on gage types for each channel. Use the d command to set. The d command also lets you set the user bit used by. Gage. Port for alternate modes in some gages and dynamic static mode. The. format is. Adxyzzzwhere x is the user bit usually 0, y is 0 for static or 1 for dynamic, and. Use a gage number of 9. For example, to set port 1 to a Federal Maxim in static mode, port 2 to a. Federal Maxim in dynamic mode, port 3 to autodetect a gage and use dynamic. Ultra. Digit III in static mode use the following 4 lines. Ad. 006. 2Bd. 016. Cd. 019. 9Dd. 006. Save your gage type and reading mode settings with the b command. You. must repeat it for each port you want to save. To save ports 1, 2, and 4 use. Ab. Bb. Db. Checking your settings. When you have made all the settings you need, you should check them to make. Timing errors or typing errors can result in the. Gage. Port NT rejecting a command you thought was accepted. Type. Ai. Bietc. for each port and compare the settings with what you expected. The return. from an i command is a string in the form. Paa,Ub. Dc,G0. 99ggg,f1h. Pk. Um. Nn. Hpor. Paa,Ub. Dc,Gddd,f1h. Pk. Um. Nn. Hpwhere aa is the port number 0. Gage. Port, b is the user. For example. P0. 1,U0. D0,G0. 990. 51,f1 2 e ,oPUNH QC Gage requires settings of for j and p, and for k, m, and n. Settings for. a, b, c, d, g, h, and i will affect how the Gage. Port interacts with the gage.